怎么安装鲁尔圆锥接头综合性能测定仪
1.压缩机与测试仪的连接:
将测试仪水平放在台面上,用一根导管将贮水器的出水口(贮水器下方)与压力控制盒(测试仪左侧)进压口连接,再用一根导管从压力控制盒的进水口连接到测试仪的进水口(测试仪左侧),重新拿一根导管连接压力控制盒的排水口。后将空压泵的电源插头插入220V电源插座内,并将空压泵电源开关按下。压缩机旁的贮水器所装的水应为纯净水或蒸馏水。水不足时应将贮水器上方的进水开关(阀门2)缓慢打开(向上),到内部气压放空后,拔掉贮水器上方管子(将插座上塑料接头按到底即可拔出),然后从贮水器上方的漏斗里注入纯净水或蒸馏水,贮满后将进水开关关闭(按到水平位置)。出厂时贮水器内未装水。
2.注射器的安装:
调节注射器安装调节螺丝(按注射器外径大小调到合适位置),用注射器外套卷边固定螺丝,将注射器外套卷边固定牢,用前后调节螺丝、上下调节螺丝、左右调节螺丝,使注射器的锥头对准测试仪左侧的标准接头,然后将左右调节螺丝旋紧。在漏液试验中,应将螺栓用螺帽固定在螺栓架上,此螺栓可调节上下位置,使其在注射器施压时能顶住注射器推杆。
3.注射针的安装:
将注射针座放在注射针座固定装置内,针头朝右,针座连接部嵌入固定装置内,用注射针固定螺丝夹紧,调节上下、前后调节螺丝,使注射针的针座对准测试仪左侧的标准接头。
ZH1962-E 鲁尔圆锥接头性能综合测试仪是根据“GB/T1962.1-2015( ISO594-1:1986)注射器、注射针及其他医疗器械 6%(鲁尔)圆锥接头一部分:通用要求”中的有关条款而设计制造的,专门用于测试圆锥接头的漏液、漏气、分离力、应力开裂等性能的测试设备。
ZH1962-E Medical Syringe and Needle Taper Joint Performance Integrative Tester It is designed and manufactured in accordance with the relevant provisions of "GB/T 1962.1-2015 (ISO594-1:1986) syringes, injection needles and other medical devices 6% (Ruhr) conical joints Part I: General requirements", and is specially designed and manufactured for testing the properties of conical joints such as leakage, leakage, separation force and stress cracking.
ZH1962-E 鲁尔圆锥接头性能综合测试仪是根据“GB/T1962.2-2001( ISO594-2:1998)注射器、注射针及其他医疗器械6%(鲁尔)圆锥接头第二部分锁定接头”中的有关条款而设计制造的,专门用于测试6%(鲁尔)圆锥接头的漏液、漏气、分离力、旋开扭矩、易装配性、抗滑丝性、应力开裂等性能的测试设备。
ZH1962-E Medical Syringe and Needle Taper Joint Performance Integrative Tester It is designed and manufactured in accordance with the relevant provisions of "GB/T1962.2-2001 (ISO594-2:1998) syringes, injection needles and other medical devices 6%(Ruhr) conical joints, part II locking joints". It is specially used to test the leakage, leakage, separation force, spinning torque, easy assembly and anti-sliding wire of 6%(Ruhr) conical joints. Special test equipment for properties, stress cracking and other properties.
ZH1962-E 测试仪由智能控制器、液晶显示屏、步进电机、步进电机驱动器、传动机构、传感器、夹具、打印机等组成。
ZH1962-E tester is composed of intelligent controller, LCD screen, stepper motor, stepper motor driver, transmission mechanism, sensor, fixture, printer and so on.
怎么安装鲁尔圆锥接头综合性能测定仪文章来源:上海远梓电子科技有限公司 刘子清